2001–2003 3.2 Acura CL Blower Motor Does Not Work.pdf

2001–2003 3.2 Acura CL Blower Motor Does Not Work
download
SYMPTOM The blower motor does not work at all. PROBABLE CAUSE Poor connection at the blower motor caused by tension on the wiring harness. CORRECTIVE ACTION Install a blower motor subharness. PARTS INFORMATION Blower Motor Subharness: P/N 04321-S0K-A00 REPAIR PROCEDURE 1. Remove the glove box and cover: • 1999–03 3.2 TL: See page 20-66 of the 1999–03 3.2 TL Service Manual. • 2001–03 3.2 CL: See page 20-64 of the 2001–03 3.2 CL Service Manual. • Online, enter keyword GLOVE, and select Glove Box Removal/Installation from the list. 2. Disconnect the brown 7P connector (C202) from the main harness. Remove the YEL/BLK wire terminal from cavity 3 of connector C202. Cut off the terminal, and tape the remaining end of the wire to the harness. NOTE: If necessary, refer to the terminal replacement section of the appropriate ETM for how to properly remove a terminal from a connector.
(Cut off the terminal and tape the end down.) (Cut off the terminal and tape the end down.) YEL/BLK WIRE BLUE/RED WIRE 3. Disconnect the 2P blower motor connector, cut off the connector, and tape the remaining ends of the wires to the pigtail. Then tape the pigtail to the main harness. 4. Disconnect the white 5P connector from the power transistor. Remove the BLU/RED wire terminal from cavity 4 of the power transistor connector. Cut off the terminal, and tape the remaining end of the wire to the harness. 5. Take the subharness, and insert the YEL/BLK wire terminal into cavity 3 of connector C202 and insert the BLU/RED wire terminal into cavity 4 of the power transistor connector. Tape both wires to the existing harness. Route the harness so there is no tension on the blower motor connector.

No comments:

Post a Comment